• DE
Skip navigation
  • News
  • Downloads
  • Product Center
  • Waterguide
  • Contact
Efficient water treatment systems Made in Germany
Skip navigation
  • Sectors

      "We have been relying on Herco's system technology for 19 years now and can testify to the reliability of the system technology and Herco's service..."

      A man in a black shirt smiles softly, symbolizing confidence in Hercowater's industrial water treatment services.

      Christian Kalbrunner
      Nierenzentrum Heidelberg (Head of Building Services and Energy Management)

    • Industry
      • Surface technology
      • Boiler feed water
      • Power Plant
      • Green hydrogen
      • Cooling water
      • Data centre
    • Industry further articles
      • Beverage industry
      • Dairy
      • Brewery
      • Laboratories and hospitals
      • Pharmaceutical industry
    • Medical
      • Hemodialysis
      • Endoscopy
      • CSSD
    • Partnerships
      • Original Equipment Manufacturers
  • Solutions & Services
      A detailed 3D model of an industrial water treatment container, showcasing reverse osmosis systems for hydrogen PEM stacks.

      The perfect water treatment solution for your needs – whether standard or customised.

    • References
      • View all Projects
    • Solutions
      • PFAS Treatment
      • Mobile Systems
      • Skid-Mounted Systems
      • Custom Systems
      • Standard Systems
    • Services
      • Regeneration and rental cartridges
      • Original-spare-parts
      • Assembly and commissioning
      • Maintenance and servicing
      • Technical support and claims
    • Services further articles
      • Trainings
      • Webinars
  • Responsibility
      Edwin Locker, Managing Director of Herco Wassertechnik GmbH, standing in a green landscape – symbolising sustainable leadership and environmentally conscious water treatment.

      Responsible practices are important for us – towards our employees, our business partners, and our environment.

    • Sustainability
      • Environmental Statement
      • EMAS
      • Carbon Neutrality
      • Donations
    • Compliance
      • Company Ethics
      • Compliance Statement
  • Company
      Two professionals discuss industrial water treatment systems in a facility, highlighting Herco's expertise in ultrapure water systems.

      Our systems meet the highest technical and hygienic requirements – tested, reliable and durable.

    • Profile
      • About us
      • Careers
      • Story
Contact us
#WaterParameters

Waterguide Icon
Waterguide

Langelier Saturation Index

Share

  • LinkedIn Icon
  • E-Mail Icon

What is the Langelier Saturation Index?

The Langelier Saturation Index, or LSI, is a calculated saturation index used to assess the saturation state of water with respect to calcium carbonate (CaCO₃).

It compares the actual measured pH of water with the theoretical pH at which the water would be exactly saturated with calcium carbonate (CaCO₃).

The Langelier Saturation Index is expressed as:

LSI = pH – pHs

where:

pH = actual measured pH of the water

pHs =theoretical calcium-carbonate saturation pH

The LSI is dimensionless.

How is the Langelier Saturation Index interpreted?

At an LSI of approximately zero, the water is in equilibrium with calcium carbonate.

LSI > 0:

The water is supersaturated with respect to calcium carbonate. Under suitable conditions, calcium carbonate may precipitate and form deposits or scale.

LSI = 0:

The water is theoretically in equilibrium with calcium carbonate.

LSI < 0:

The water is undersaturated with respect to calcium carbonate and has a tendency to dissolve existing calcium carbonate.

A negative LSI should not automatically be interpreted as proof that the water is generally corrosive towards all metallic materials. The Langelier Index primarily describes the saturation state of calcium carbonate. Corrosion is influenced by many additional factors.

Which water parameters influence the LSI?

The calculation of the LSI and the saturation pH mainly requires:

  • pH
  • temperature
  • calcium hardness as CaCO₃
  • Total alkalinity as CaCO₃, often derived from the acid-neutralising capacity KS₄,₃
  • total dissolved solids (TDS)

Together, these parameters determine the calculated calcium-carbonate saturation state. The approximation accounts for their effects in a simplified manner; activity effects become increasingly important at high ionic strength.

As pH increases, for example, the proportion of carbonate ions generally increases. Together with calcium, these ions can form calcium carbonate:

Ca²⁺ + CO₃²⁻ → CaCO₃

Temperature also affects calcium-carbonate saturation. With the other input variables held constant, a higher temperature in the approximation used here typically lowers the saturation pH and therefore increases the calculated LSI.

How is the saturation pH calculated?

In practice, the saturation pH is generally calculated using appropriate calculation methods or design software.

It should be noted that simplified LSI calculations have limited applicability, particularly at high salt concentrations or high ionic strength.

Why is the LSI important for reverse osmosis systems?

In a reverse osmosis system, part of the feed water passes through the membrane as permeate, while most dissolved salts remain on the concentrate side.

As recovery increases, rejected or only partly permeating constituents become more concentrated in the concentrate stream. These typically include calcium and bicarbonate; the actual concentration increase depends on membrane rejection, recovery and any precipitation or chemical reactions that occur.

When assessing a reverse osmosis system, the LSI of the raw water is therefore not the primary consideration. Instead, the relevant value is the LSI under the prevailing concentrate conditions or at the worst-case operating point. This is where the concentration of rejected dissolved constituents is highest, and consequently where the risk of calcium carbonate supersaturation is greatest.

As a result, the risk of calcium carbonate scaling on the concentrate side of a reverse osmosis system can be significantly higher than in the original feed water.

The Langelier Saturation Index is therefore an important parameter for assessing the risk of calcium carbonate scaling. However, the design of a specific RO system must also take account of recovery, temperature, pH, membrane rejection and the saturation of other sparingly soluble salts.

In principle, antiscalants do not reduce the calculated LSI. However, they can inhibit crystal formation and crystal growth, thereby enabling operation under conditions of a certain degree of supersaturation. The permissible limits must be checked for the specific product being used.

How does pH affect the LSI?

The pH value has a particularly strong influence on the LSI. As pH increases, the lime–carbonic acid equilibrium shifts towards a higher proportion of carbonate ions. In the presence of calcium, this increases the tendency towards calcium carbonate supersaturation. A reduction in pH therefore often results in a lower LSI.

What are the limitations of the Langelier Saturation Index?

The Langelier Saturation Index (LSI) is a saturation index and does not directly predict the actual amount of scale that will form.

A positive value does not necessarily mean that significant scale deposits will form immediately. Whether and how quickly calcium carbonate precipitates also depends on factors such as surface characteristics, flow conditions, residence time, temperature, crystallisation nuclei and water composition. Similarly, a negative LSI does not automatically mean that a pipe will corrode.

At higher salinity levels or ionic strengths, the classical LSI calculation becomes increasingly inaccurate. In membrane technology, alternative saturation indices or thermodynamic calculation methods are therefore used, depending on the water composition and the design methodology applied. Some membrane manufacturers and design software packages use the LSI only up to certain salinity levels and switch to other calculation methods at higher TDS values, such as the Stiff-Davis Stability Index.

The following values are used as reference and reporting limits for the LSI:

  • -2.8: corresponds to highly corrosive water

  • +2.8: corresponds to water with a strong tendency to precipitate calcium carbonate (scale-forming water)

LSI values above +2.8 and below -2.8 are considered critical risk ranges or alarm thresholds for the system.

At values above +2.8, calcium carbonate may precipitate extensively and uncontrollably. At values below -2.8, the water has an increased potential to dissolve existing solid calcium carbonate. However, no direct conclusions can be drawn regarding the corrosion rate of metallic materials.

Why is the Langelier Saturation Index important in water treatment?

The LSI serves as a rapid indicator for assessing the calcium carbonate saturation of water. It is particularly useful for estimating the risk of scale formation in pipes, heat exchangers and reverse osmosis systems. However, for a reliable assessment of a system, the LSI should always be considered alongside the complete water analysis and the specific operating conditions.

The LSI assesses only saturation with respect to calcium carbonate. Other scaling risks, such as calcium sulphate, barium sulphate, strontium sulphate, calcium fluoride and silicates, must be assessed separately.

Share

  • LinkedIn Icon
  • E-Mail Icon

Feel free to sign up for our newsletter
All company news at a glance

By registering, I agree to receive the Herco newsletter with information and offers by email. My usage behavior will be evaluated for analysis and optimization purposes. I can revoke my consent at any time. Further information can be found in our privacy policy.
Thank you for signing up!

An email has just been sent to you.
Please click the link it contains to confirm your subscription.
Skip navigation
  • Imprint
  • Privacy policy
  • Terms and conditions
  • Whistleblower System
Network
LinkedIn Icon
Youtube Icon
Educate yourself
Made in Germany